this publication, including its validity, is available in the IEC Catalogue of .. IEC , Dimensions of mechanical structures of the ,6 mm (19 in). Buy IEC Ed. Dimensions of mechanical structures of the mm ( 19 in) series. Part 1: Panels and racks from SAI Global. Find the most up-to-date version of IEC at Engineering

Author: Dout Moogurn
Country: Montenegro
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 27 April 2004
Pages: 417
PDF File Size: 6.26 Mb
ePub File Size: 1.20 Mb
ISBN: 142-2-63731-281-5
Downloads: 9242
Price: Free* [*Free Regsitration Required]
Uploader: Zuramar

A difficulty with forced air fan cooling in rack equipment is that fans can fail due to iev or dust. They allow for dense hardware configurations without occupying excessive floorspace or requiring shelving. Archived from the original on For rack mounted computer servers, devices generally intake air on the front and exhaust on the rear.

Thus, a 1U rackmount computer is not 1. The amount of motion and resulting stress depends on the structural characteristics of the building and framework 60927-1 which the equipment is contained, iwc the severity of the earthquake. Ina durable fiber reinforced plastic inch rackmount case was patented by ECS Composites and became widely used in military and commercial applications for electronic deployment and operation.

See also Ief PC. The holes are large enough to permit a bolt to be freely inserted through without binding, and bolts are fastened in place using cage nuts. The outer shell is frequently embossed in a self-mating pattern to combat the tendency for stacked cases to deform slightly creating a slope that encourages the upper case to slide off.

Since the mounting hole arrangement is vertically symmetric, it is possible to mount rack-mountable equipment upside-down.

inch rack – Wikipedia

Common uses include server, telecom, broadcast video, lighting, audio, and scientific lab equipment. Racks carrying telecom equipment like routers and switches often have extra width to accommodate the many cables on the sides.

Byit 602977-1 an established standard with holes tapped for screws with alternating spacings of 1. The rails may also be able to fully support the equipment in a position where it has been slid clear of the rack; this isc useful for inspection or maintenance of equipment which will then be slid back into the rack. The term relay rack appears on page at the bottom of column 1.

  75345P DATASHEET PDF

List of International Electrotechnical Commission standards. Raised or false floor cooling in server rooms can serve a similar purpose; they permit cooling airflow to equipment through the underfloor space to the underside of enclosed rack cabinets.

An enclosed sealed cabinet with forced air fans permits air filtration to protect equipment from dust. A variety of airflow patterns can be found, including front intakes and rear exhausts, as well as side intakes and exhausts.

IEC | IEC Webstore

This of course varies by manufacturer, the design of the rack and its purpose, but through common constraining factors such as raised floor tile dimensionsthese dimensions have become quite common. Newer server rack cabinets come with adjustable mounting rails allowing the user to place the rails at a shorter depth if needed. Rack-mountable equipment is usually designed to occupy some integer number of U. The shape of small cases is maintained by the rack rails and the cover seal extrusions alone.

The height of a rack can vary from a few inches, such as in a broadcast console, to a floor mounted rack whose interior is 45 rack units Although open-frame racks are the least expensive, they also expose air-cooled equipment to dust, lint, and other environmental contamination. Hole spacing is 25 millimetres 0. This prevents circular airflows where hot exhaust air is recirculated through an adjacent device and causes overheating. Equipment can be 60297–1 either close to its center of gravity to minimize load on its front panelor via the equipment’s front panel holes.

The size denotes the width of the faceplate for the installed equipment. However, not all equipment is suitable for 600297-1 type of mounting. Open Rack is a mounting 62097-1 designed by Facebook ‘s Open Compute Project that has the same outside dimensions as typical inch racks e.

The First Stored Program Computer. There are a multitude of specialty server racks including soundproof server racks, air conditioned server racks, NEMA rated, seismic rated, open frame, narrow, and even miniature inch racks for smaller applications. Patent 2,granted Oct.

Equipment designed to be placed in a rack is typically described as rack-mountrack-mount instrumenta rack mounted systema rack mount chassissubrackrack mountableor occasionally simply shelf. For example, an oscilloscope might be 4U high, and rack-mountable computers are mostly between 1U and 4U high.

Threaded mounting holes in racks where the equipment is frequently changed are problematic because the threads can be damaged or the mounting screws can break off; both problems render the mounting hole unusable. End covers are typically secured with either a simple draw latch or a rotary cam “butterfly” latch, named for the shape of the twist handle. Wikimedia Foundation servers as seen from the front.

  HALAWIYAT CHOUMICHA 2009 PDF

According to Telcordia Technologies Generic Requirements document GRCORE, during an earthquake, telecommunications equipment is subjected to motions that can over-stress equipment framework, circuit boards, and connectors. Heavy equipment or equipment which is commonly accessed for servicing, for which attaching or detaching at all four corners simultaneously would pose a problem, is often not mounted directly onto the rack but instead is mounted via rails or slides.

A inch rack is a standardized frame or enclosure for mounting multiple electronic equipment modules. The fans themselves can be difficult to replace. For instance, most optical disc players will not work upside-down because the driving motor mechanism does not grip the disc. Road cases are typically made from polyvinyl chloride PVC laminated plywood sides, joined by extruded aluminum edging, steel corners, handles and latches. The height of the electronic modules is also standardized as multiples of 1.

19-inch rack

When rack rails are too thin to tap, rivnuts or other threaded inserts can be used, and when the particular class of equipment to be mounted is known in advance, some of the holes can be omitted from the mounting rails. The extra width and depth enables cabling to be routed with ease also helping to maintain bend-radius for fibre and copper cables and deeper equipment to be utilised.

The next innovation in rack design has been the square-hole rack. Production of clearance-hole racks is less expensive because tapping the holes is eliminated and replaced with fewer, less expensive, cage nuts.

There is no standard for airflow and cooling of rack mounted equipment. Rack Cabinet Buying Guide, http: Tapping large numbers of holes that may never be used is expensive; nonetheless tapped-hole racks are still in use, generally for hardware that rarely changes. The gap between the posts is millimetres