Status: Alert Withdrawn. Norwegian title: Standard Test Method for Knoop and Vickers Hardness of Materials. English title: Standard Test Method for Knoop and . ASTM Ee2. Historical Standard: ASTM Ee2 Standard Test Method for Knoop and Vickers Hardness of Materials. SUPERSEDED (see Active link. ASTM Ee2. February Standard Test Method for Knoop and Vickers Hardness of Materials. Historical Version.

Author: Femuro Gardakasa
Country: Ghana
Language: English (Spanish)
Genre: Sex
Published (Last): 20 May 2005
Pages: 368
PDF File Size: 18.28 Mb
ePub File Size: 14.7 Mb
ISBN: 792-1-93658-844-6
Downloads: 41545
Price: Free* [*Free Regsitration Required]
Uploader: Zugal

On examination, accident investigators found that the sub-standard pins had a hardness value of only some HV5. Print 1 2 3 4 5 page sstarting from page current page. Vickers hardness numbers are reported as xxxHVyye. Vickers Hardness Testing of Metallic Material that was under the jurisdiction of.

The last approved version of this historical standard is referenced. The last approved version of this historical standard is referenced on www. The difference in length of both diagonals and the illumination gradient, are both classic indications of an out-of-level sample.

Vickers hardness test

The hardness number can be converted into units of pascalssatm should not be confused with pressure, which also has units of pascals. No further reproductions authorized. Subscription – always available and updated A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition. Please sign into an account with a subscription to this content, or email for help at support ee384.

ASTM Ee1《材料的努氏和维氏硬度标准试验方法》美国标准(英文版)

With this revision the test method was expanded to include the requirements previously defined in E Enter your account email address to request a password reset: As a rule of thumb the sample thickness should be kept greater than 2. Some manufactures are 10f2 that they have watch glass at Vickers compared to other watches rating at NOTE 1—Previous versions of this standard limited test forces to 9.

  LA MARIQUITA MALHUMORADA PDF

Originally approved in Sandland at Vickers Ltd as an alternative to the Brinell method to measure the hardness of materials. Current edition approved Aug. The angle was varied experimentally and it was found that the hardness value obtained on a homogeneous piece of material remained constant, irrespective of load.

This leads to the following equation: To calculate Vickers hardness number using SI units one needs to convert the force applied from newtons to kilogram-force by dividing by 9. The right to access the electronic files of ASTM Standards is for purposes of viewing for individual use only.

Vickers hardness test A Vickers hardness tester.

Monitoring Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work. Metallography and is the direct responsibility of Subcommittee E The electronic file may not be reproduced in any way.

If you need to be able to add standards to the monitoring service, you must register as a user with your own username and password. No items in cart. Currently some watch companies are improving the crystal watch glass by testing the strength using the Vickers hardness test.

Vickers hardness test

Content only available by subscription. ASTM grants you a license as follows: The Vickers test can be used for all metals and has one of the widest scales among hardness tests.

However, because of the historical precedent and continued common usage, force values in gf and kgf units are provided for information and much of the discussion in this standard as well as the method of reporting the test results refers to these units. You currently cannot view this content.

  JOHAN NORBERG IN DEFENSE OF GLOBAL CAPITALISM PDF

ASTM E384:10e2

A diamond in the form of a square-based pyramid satisfied these conditions. For thin samples indentation depth can be an issue due to substrate effects.

A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition. NOTE 2—While Committee E04 is primarily concerned with metals, the test procedures described f384 applicable to other materials. Register for a trial account.

The basic principle, as with all common measures of hardness, is to observe the questioned material’s ability to resist plastic deformation from a astmm source. This standard is issued under the fixed designation E; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year aatm last revision.

Last atsm edition approved in as E — 10e2. However, on the aircraft flying Partnair Flight the pins were later found to have been replaced with sub-standard parts, leading to rapid wear and finally loss of the aircraft. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Remember me for one month. Please login to your authorized staff account to use this feature.

The fin attachment pins and sleeves in the Convair airliner were specified by the aircraft manufacturer to be hardened to a Vickers Hardness specification of HV5, the ‘5’ meaning five kiloponds.

Start Webshop Product catalog Product presentation. This ensures that w384 are always up-to-date and saves you both time and money.