Light and lighting – Sports lighting; German version EN The DIN EN “Sports Location Lighting” standard regulates minimum optimal lighting levels, and depending on the type of sport and level of competition it. Draft standard DIN EN – Draft. Light and lighting – Sports lighting; German and English version prEN German title: Licht.

Author: Gule Gorg
Country: Monaco
Language: English (Spanish)
Genre: Travel
Published (Last): 17 November 2004
Pages: 359
PDF File Size: 11.90 Mb
ePub File Size: 11.86 Mb
ISBN: 215-3-23425-869-2
Downloads: 39289
Price: Free* [*Free Regsitration Required]
Uploader: Negal

Tl Increase in threshold value, measure of the loss of visibility of a visual object as a result of physiological glare caused by excessively bright luminaires. It must be possible to switch the lighting system for pedestrian crossings independently.

Reference values for illumination ยท BEGA

By continuing to visit our website you consent to the use of cookies. BEGA uses cookies to improve your browsing experience. SR Environment illuminance ratio to improve spatial orientation, so that the areas beside the carriageway, if not illuminated themselves, are still recognisable. Arealkrav til aktivitetssal er. Health care technology The DIN EN “Sports Location Lighting” standard regulates minimum optimal lighting levels, and depending on the type of sport and level of competition it Guidance on the work environment.

We wish you a pleasant end-of-year holiday. For the uniform evaluation of the illumination in the region of pedestrian crossings, a rectangular horizontal evaluation field is agreed.

Glossary Subject index List of tables List of ein List of references Standards Guidelines and instructions European directives and regulations Further publications Lighting societies Standardisation institutes.

  AVENTURE ET SURVIE JOHN WISEMAN PDF

Log In Sign Up.

LIGHTING IN SPORTS FACILITIES | Gossen

Ul Longitudinal uniformity, relationship between the lowest and the highest luminance on the centre line of a traffic lane. Textile and leather technology They are therefore not suitable for the promotion of our products for the purpose of resale by the user. All requirements are meant to be as minimum requirements. Glass and ceramics industries The lighting classes of the outdoor rinks are defined in the standard EN General traffic areas for outdoor work places.

Constant handling of large components and raw materials, loading and unloading of freight, operating areas of cranes, open loading platforms.

Reference values for illumination

Lys og belysning – Sportsbelysning. This particularly applies in the context of planning services, consultations and tendering processes. Rin features of the individual types of sports must be taken into account. Low volume of traffic Car parks for shops, terraced houses and apartment blocks, parking areas for bicycles. Unlike road lighting, the illumination at the pedestrian crossing must not be switched off during the hours of darkness.

No djn rights will be granted in this regard. Company organization, management and quality. Any use extending beyond this purpose must be licenced in writing by BEGA. Workstation layout and postural requirements. Fluid systems and components for general use Analysis and compliance test methods for electronic 1219 displays ISO Choose country and language: Beuth Verlag Lighting codes, standards and An error has occurred.

Lighting requirements are defined by.

  KATHY SIERRA SCJP 1.7 PDF

Back Products Indoor lighting Continuous line luminaires and batten luminaires Luminaires with higher degree of protection Recessed luminaires Surface-mounted luminaires Suspended luminaires Downlights and spotlights Wall-mounted luminaires Free-standing and desktop luminaires Industrial luminaires Ballproof luminaires Trunking rails and trunking profiles Replacement diffusers Awards Outdoor lighting Post-top luminaires Suspended luminaires Bollard luminaires Pillar luminaires Wall- and ceiling-mounted luminaires Ground-recessed luminaires Spotlight Floodlight Awards Light management LiveLink light management system Energy-saving systems Colour control systems Manual controls Applications Office Lighting for offices References Industry Lighting for industry Industry 4.

This document is a preview generated by EVS Petroleum and related technologies The technical standards not provide sufficient information on the measurement procedures, especially for vertical illuminance.

Apart from the tabular information, the standard specifies further quality requirements for each sport: Medium volume of traffic Car parks for department stores, office buildings, factories, em facilities and multi-purpose halls. Construction materials and building Lighting requirements for safety and security of outdoor work places.

To find out more, please check our terms of use. Illumination class I Top competitions, top performance training; spectators: This product is already on the project list. More information on cookies.

The following recommendations apply for the height of the measuring levels: Minimum degree of illuminance E h min [lx]. Aircraft and space vehicle engineering